Accuracy class
Class 0.5S active energy conforming to IEC 62053-22
Class 1 active energy conforming to IEC 62053-21
Class 2 reactive energy conforming to IEC 62053-23
Class C active energy conforming to EN 50470-3
Measurement accuracy
Voltage 0.3 % 50...330 V
Voltage 0.3 % 80...570 V
Current 0.3 % 0.5...6 A
Current 0.5 % 0.1...1.2 A
Power quality analysis
Power factor (PF)
Total harmonic distortion (THD)
Product or component type
Energy meter
Range of product
PowerLogic
Rated supply voltage [Us]
100...277 V AC 45...65 Hz
100...300 V DC
173...480 V AC 45...65 Hz
Type of measurement
Active power
Reactive power
Energy
Power factor
Frequency
Voltage
Apparent power
Total voltage harmonic distortion THD (U)
Total current harmonic distortion THD (I)
Current
Complementary
Communication port protocol
Modbus at 9.6...38.4 kbauds
Communication port support
RS485
Data recording
15 alarms
Time stamping
Min/max of instantaneous values
Energy consumption logs
Power logs
Complementary Depth
70 mm
Display resolution
128 x 96 pixels
Frequency measurement range
45...65 Hz
Complementary Height
95 mm
Information displayed
Tariff (4)
Network frequency
50 Hz
60 Hz
Number of inputs
2 digital 0...4 mA 11...40 V DC
Number of outputs
2 digital
Sampling rate
32 samples/cycle
Standards
EN 50470-1
EN 50470-3
EN 61010-1
EN 61557-12
IEC 61557-12
IEC 62052-11
UL 61010-1
Target application
Residential
Industry cost management: cost allocation: sub feeder
Industry cost management: billing: sub feeder
Small commercial
Buildings small building cost management: cost allocation: sub feeder
Buildings small building cost management: billing: sub feeder
Data center cost management: cost allocation: sub feeder
Data center cost management: billing: sub feeder
Buildings medium building cost management: cost allocation: sub feeder
Buildings medium building cost management: billing: sub feeder
Buildings multi-site cost management: cost allocation: sub feeder
Buildings multi-site cost management: billing: sub feeder
Buildings large building cost management: cost allocation: sub feeder
Buildings large building cost management: billing: sub feeder
Healthcare cost management: cost allocation: sub feeder
Healthcare cost management: billing: sub feeder
Type of measurement
Active power
Reactive power
Energy
Power factor
Frequency
Voltage
Apparent power
Total voltage harmonic distortion THD (U)
Total current harmonic distortion THD (I)
Current
Voltage measurement range
50-330 V AC 45...65 Hz phase to neutral
50-330 V AC 45...65 Hz direct
570-999000 V AC 45...65 Hz with external VT
80-570 V AC 45...65 Hz phase to phase
80-570 V AC 45...65 Hz direct
Complementary Width
90 mm
Enviroment
Ambient air temperature for operation
-25...55 °C
Ambient air temperature for storage
-40...85 °C
Electromagnetic compatibility
1.2/50 µs shock waves immunity test level 4 conforming to IEC 61000-4-5
Electrostatic discharge level 4 conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8
Conducted and radiated emissions class B conforming to EN 55022
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
IP degree of protection
IP20 body: conforming to IEC 60529
IP40 front panel: conforming to IEC 60529
Operating altitude
< 3000 m
Overvoltage category
III conforming to IEC 61010-1
Relative humidity
5...95 % at 50 °C
Standards
EN 50470-1
EN 50470-3
EN 61010-1
EN 61557-12
IEC 61557-12
IEC 62052-11
UL 61010-1