PM2110 – Power & Energy meter – THD – LED display – Pulse output – Class 1

Short description

PM2110 – Power & Energy meter – THD – LED display – Pulse output – Class 1

Brand
Schneider Electric
Product name
EasyLogic PM2100
Accuracy class [Ea]
Class 1
Best for
New installation
Communication
Without
Current measurement method
External CT 1A/5A
Current measurement range
5...6000 mA
Device application
Sub billing
Power monitoring
MID compliant
No
Mounting mode
Panel/door
Multi-tariff
No
Power quality data
Yes (PF, THD)
Rated current [In]
1 A (CT input)
5 A (CT input)
Type of measurement
Active energy total
Reactive energy total
Active power total
Reactive power total
Power factor average
Frequency average
Voltage average
Apparent energy total
Apparent power total
THD (U) per phase
THD (I) per phase
Current average

5 pieces available in 2-4 days

6+ pieces available in 6-8 days

133,00  excl. VAT
Price Range
Amount (pcs)Price
1+133.00 €
5+131.00 €
10+129.00 €

Description

EasyLogic PM2110 meter is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having three rows of bright red four-digit numbers 14.2 mm height LED display. The meter measures active energy as per accuracy Class Class 1.0 in accordance with the IEC 62053-21 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion for both current and voltage on per phase basis. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 44 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. It offers up to thirteen possible wire configurations for Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. The meter also has one digital pulse output for any energy parameters congigurable to different energy scaling. Product measured values are as follows: width 96 mm, depth 54 mm, height 96 mm and product weight 300 g.

Specifications

Main
Accuracy class
Class 1 active energy conforming to IEC 62053-21
Class 1 reactive energy conforming to IEC 62053-24
Device short name
PM2110
Measurement accuracy
Active energy +/- 1 %
Active power +/- 1 %
Power factor +/- 0.01
Frequency +/- 0.05 %
Reactive energy +/- 1 %
Voltage +/- 0.5 %
Apparent power +/- 1 %
Current +/- 0.5 %
Power quality analysis
Power factor (PF)
Total harmonic distortion (THD)
Product or component type
Energy meter
Range of product
EasyLogic
Rated supply voltage [Us]
44...277 V AC 45...65 Hz +/- 10 %
44...277 V DC +/- 10 %
Type of measurement
Active energy total
Reactive energy total
Active power total
Reactive power total
Power factor average
Frequency average
Voltage average
Apparent energy total
Apparent power total
THD (U) per phase
THD (I) per phase
Current average
Complementary
Communication port protocol
POP
Complementary Depth
61.64 mm embedded
76.09 mm total
Display type
7 segments LED
Electrical insulation class
Class II
Double insulation
Frequency measurement range
45...65 Hz
Complementary Height
96 mm
Impulse duration
20 ms
Information displayed
Active power
Power factor
Frequency
Harmonic distortion
Reactive power
Voltage
Apparent power
Unbalanced in %
Demand power (past value)
Demand power (present value)
Demand current (past value)
Demand current (present value)
Energy consumption
Current
Input impedance
Voltage (impedance > 5 MOhm)
Current (impedance <= 0.3 mOhm)
Local signalling
Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operating (RUN)
Maximum power consumption in VA
6 VA at 277 V AC
Maximum power consumption in W
2 W at 277 V (power lines (DC))
3.3 W (power lines (AC))
Net weight
300 g
Network frequency
50 Hz
60 Hz
Number of outputs
1 pulse
Sampling rate
64 samples/cycle
Type of measurement
Active energy total
Reactive energy total
Active power total
Reactive power total
Power factor average
Frequency average
Voltage average
Apparent energy total
Apparent power total
THD (U) per phase
THD (I) per phase
Current average
Voltage measurement range
20-277 V AC 50/60 Hz between phase and neutral
35-480 V AC 50/60 Hz between phases
480-999000 V AC 50/60 Hz with external VT
Complementary Width
96 mm
Enviroment
Ambient air temperature for operation
-10...60 °C
Ambient air temperature for storage
-25...70 °C
Electromagnetic compatibility
Electrostatic discharge conforming to IEC 61000-4-2
Emission tests conforming to FCC part 15 class A
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Magnetic field at power frequency conforming to IEC 61000-4-8
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Conducted RF disturbances conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
IP degree of protection
IP30 body: conforming to IEC 60529
IP54 front: conforming to IEC 60529
Net weight
300 g
Operating altitude
< 2000 m
Overvoltage category
III conforming to IEC 61010-1
Relative humidity
5...95 % at 50 °C