PM2230 – Power & Energy meter – up to 31st harmonic – LCD display – RS485 – Class 0.5S

Short description

PM2230 – Power & Energy meter – up to 31st harmonic – LCD display – RS485 – Class 0.5S

Brand
Schneider Electric
Product name
EasyLogic PM2200
Accuracy class [Ea]
Class 0.5S
Best for
New installation
Communication
Modbus RS485
Current measurement method
External CT 1A/5A
Current measurement range
5...6000 mA
Device application
Sub billing
Power monitoring
MID compliant
No
Mounting mode
Panel/door
Multi-tariff
No
Power quality data
Yes (Intermediate)
Rated current [In]
1 A (CT input)
5 A (CT input)
Type of measurement
Active energy total
Reactive energy total
Active power min/max, total
Reactive power min/max, total
Power factor min/max, avg
Frequency min/max, avg
Voltage min/max, avg
Apparent energy total
Apparent power min/max, total
THD (U) per phase
THD (I) per phase
Current min/max, avg

1 pieces available in 2-4 days

2+ pieces available in 6-8 days

235,00  excl. VAT
Price Range
Amount (pcs)Price
1+235.00 €
5+231.00 €
10+227.00 €

Description

EasyLogic PM2230 meter is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having backlit LCD display of 128 by 128 pixels. The meter measures active energy as per accuracy Class Class 0.5S in accordance with the IEC 62053-22 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion and Individual harmonics up to 31st Harmonic order. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 80 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. It offers up to thirteen possible wire configurations for Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. It is having RS485 communication port over Modbus RTU protocol. The meter can be upgraded with optional add on IO modules for WAGES monitoring. These module comes with either two channels each of digital inputs and outputs or analog inputs and outputs. This version can be configured for 23 different types of alarms stored in 40 registers. Product measured values are as follows: width 96 mm, depth 54 mm, height 96 mm and product weight 300 g.

Specifications

Main
Accuracy class
Class 0.5S active energy conforming to IEC 62053-22
Class 1 reactive energy conforming to IEC 62053-24
Class 5 harmonic distorsion (I THD & U THD)
Device short name
PM2230
Measurement accuracy
Active energy +/- 0.5 %
Active power +/- 0.5 %
Power factor +/- 0.01
Frequency +/- 0.05 %
Reactive energy +/- 1 %
Voltage +/- 0.5 %
Apparent power +/- 0.5 %
Current +/- 0.5 %
Power quality analysis
Up to the 31st harmonic
Power factor (PF)
Total harmonic distortion (THD)
Product or component type
Power Quality Analyzer
Range of product
EasyLogic
Rated supply voltage [Us]
100...277 V DC +/- 10 %
80...277 V AC 45...65 Hz +/- 10 %
Type of measurement
Active energy total
Reactive energy total
Active power min/max, total
Reactive power min/max, total
Power factor min/max, avg
Frequency min/max, avg
Voltage min/max, avg
Apparent energy total
Apparent power min/max, total
THD (U) per phase
THD (I) per phase
Current min/max, avg
Complementary
Communication port protocol
Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Communication port support
RS485
Data recording
Time stamping
Min/max for 8 parameters
Energy consumption logs
Power logs
Complementary Depth
61.64 mm embedded
76.09 mm total
Display resolution
128 x 128 pixels
Display type
Backlit LCD
Electrical insulation class
Class II
Double insulation
Frequency measurement range
45...65 Hz
Complementary Height
96 mm
Information displayed
Harmonic amplitude
Active power
Power factor
Frequency
Harmonic distortion
Reactive power
Voltage
Apparent power
Unbalanced in %
Demand power (past value)
Demand power (present value)
Demand current (past value)
Demand current (present value)
Energy consumption
Current
Input impedance
Voltage (impedance > 5 MOhm)
Current (impedance <= 0.3 mOhm)
Local signalling
Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communication
Maximum power consumption in VA
8 VA at 277 V AC
Maximum power consumption in W
3.3 W (power lines (AC))
3.3 W at 277 V (power lines (DC))
Net weight
300 g
Network frequency
50 Hz
60 Hz
Sampling rate
64 samples/cycle
Type of measurement
Active energy total
Reactive energy total
Active power min/max, total
Reactive power min/max, total
Power factor min/max, avg
Frequency min/max, avg
Voltage min/max, avg
Apparent energy total
Apparent power min/max, total
THD (U) per phase
THD (I) per phase
Current min/max, avg
Voltage measurement range
20-277 V AC 50/60 Hz between phase and neutral
35-480 V AC 50/60 Hz between phases
480-999000 V AC 50/60 Hz with external VT
Complementary Width
96 mm
Enviroment
Ambient air temperature for operation
-10...60 °C
Ambient air temperature for storage
-25...70 °C
Electromagnetic compatibility
Electrostatic discharge conforming to IEC 61000-4-2
Emission tests conforming to FCC part 15 class A
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Magnetic field at power frequency conforming to IEC 61000-4-8
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Conducted RF disturbances conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
IP degree of protection
IP30 body: conforming to IEC 60529
IP54 front: conforming to IEC 60529
Net weight
300 g
Operating altitude
< 2000 m
Overvoltage category
III conforming to IEC 61010-1
Relative humidity
5...95 % at 50 °C