Main
Accuracy class
Class 0.5S active energy conforming to IEC 62053-22
Measurement accuracy
Active energy +/- 0.5 %
Active power +/- 0.5 %
Power factor +/- 0.005
Frequency +/- 0.05 %
Reactive energy +/- 2 %
Voltage +/- 0.5 %
Apparent power +/- 0.5 %
Current +/- 0.5 %
Power quality analysis
Up to the 15th harmonic
Power factor (PF)
Total harmonic distortion (THD)
Product or component type
Power Quality Analyzer
Range of product
PowerLogic
Rated supply voltage [Us]
100...415 V AC 45...65 Hz
125...250 V DC
Type of measurement
Active power
Reactive power
Energy
Power factor
Frequency
Voltage
THD (U) per phase
THD (I) per phase
Current
Complementary
Communication port protocol
JBUS
Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V
Communication port support
RS485
Data recording
Time stamping
Min/max of instantaneous values
Complementary Depth
72 mm
Display resolution
128 x 128 pixels
Frequency measurement range
45...65 Hz
Complementary Height
96 mm
Input impedance
Voltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)
Maximum power consumption in VA
10 VA at 415 V
Network frequency
50 Hz
60 Hz
Number of outputs
1 digital
Sampling rate
64 samples/cycle
Standards
EN 50470-1
EN 50470-3
IEC 60529
IEC 61557-12
IEC 62053-22
IEC 62053-24
UL 61010-1
Target application
Industry cost management: cost allocation: main incomer
Industry cost management: billing: main incomer
Industry network management: sub feeder
Industry cost management: cost allocation: sub feeder
Industry cost management: billing: sub feeder
Buildings small building cost management: cost allocation: main incomer
Buildings small building cost management: cost allocation: sub feeder
Buildings small building cost management: billing: sub feeder
Buildings small building network management: main incomer
Buildings small building network management: sub feeder
Data center cost management: billing: main incomer
Data center network management: sub feeder
Data center cost management: cost allocation: main incomer
Data center cost management: cost allocation: sub feeder
Data center cost management: billing: sub feeder
Buildings medium building network management: main incomer
Buildings medium building cost management: cost allocation: main incomer
Buildings medium building cost management: billing: main incomer
Buildings medium building cost management: cost allocation: sub feeder
Buildings medium building cost management: billing: sub feeder
Buildings medium building network management: sub feeder
Buildings multi-site cost management: cost allocation: main incomer
Buildings multi-site cost management: billing: main incomer
Buildings multi-site network management: sub feeder
Buildings multi-site cost management: cost allocation: sub feeder
Buildings multi-site cost management: billing: sub feeder
Buildings small building cost management: billing: main incomer
Buildings large building cost management: cost allocation: main incomer
Buildings large building cost management: billing: main incomer
Buildings large building network management: sub feeder
Buildings large building cost management: cost allocation: sub feeder
Buildings large building cost management: billing: sub feeder
Healthcare cost management: cost allocation: main incomer
Healthcare cost management: billing: main incomer
Healthcare network management: sub feeder
Healthcare cost management: cost allocation: sub feeder
Healthcare cost management: billing: sub feeder
Type of measurement
Active power
Reactive power
Energy
Power factor
Frequency
Voltage
THD (U) per phase
THD (I) per phase
Current
Voltage measurement range
20-400 V AC 45...65 Hz between phase and neutral
35-690 V AC 45...65 Hz between phases
Complementary Width
96 mm
Enviroment
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...85 °C
Electromagnetic compatibility
Electrostatic discharge level 4 conforming to IEC 61000-4-2
Limits for harmonic current emissions class A conforming to IEC 61000-3-2
Magnetic field at power frequency level 4 conforming to IEC 61000-4-8
Conducted and radiated emissions class B conforming to EN 55022
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
IP degree of protection
IP30 body: conforming to IEC 60529
IP52 front: conforming to IEC 60529
Operating altitude
< 2000 m
Relative humidity
5...95 % at 50 °C
Standards
EN 50470-1
EN 50470-3
IEC 60529
IEC 61557-12
IEC 62053-22
IEC 62053-24
UL 61010-1