Accuracy class
Class 0.5S active energy conforming to IEC 62053-22
Measurement accuracy
Active energy +/- 0.5 %
Active power +/- 0.5 %
Power factor +/- 0.005
Frequency +/- 0.05 %
Reactive energy +/- 2 %
Voltage +/- 0.5 %
Apparent power +/- 0.5 %
Current +/- 0.5 %
Power quality analysis
Up to the 31st harmonic
Power factor (PF)
Total harmonic distortion (THD)
Product or component type
Power Quality Analyzer
Range of product
PowerLogic
Rated supply voltage [Us]
100...415 V AC 45...65 Hz
125...250 V DC
Type of measurement
Active power
Reactive power
Energy
Power factor
Frequency
Voltage
THD (U) per phase
THD (I) per phase
Current
Complementary
Communication port protocol
BACnet IP
Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V
Communication port support
Ethernet
Data recording
Time stamping
Min/max of instantaneous values
Alarm logs
Event logs
Data logs
Maintenance logs
Complementary Depth
72 mm
Display resolution
128 x 128 pixels
Frequency measurement range
45...65 Hz
Complementary Height
96 mm
Information displayed
Tariff (4)
Input impedance
Voltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)
Maximum power consumption in VA
10 VA at 415 V
Network frequency
50 Hz
60 Hz
Number of inputs
2 digital
Number of outputs
2 digital
2 relay
Sampling rate
64 samples/cycle
Standards
EN 50470-1
EN 50470-3
IEC 60529
IEC 61557-12
IEC 62053-22
IEC 62053-24
UL 61010-1
Target application
Industry cost management: cost allocation: main incomer
Industry cost management: billing: main incomer
Industry network management: sub feeder
Industry cost management: cost allocation: sub feeder
Industry cost management: billing: sub feeder
Buildings small building cost management: cost allocation: main incomer
Buildings small building cost management: cost allocation: sub feeder
Buildings small building cost management: billing: sub feeder
Buildings small building network management: main incomer
Buildings small building network management: sub feeder
Data center cost management: billing: main incomer
Data center network management: sub feeder
Data center cost management: cost allocation: main incomer
Data center cost management: cost allocation: sub feeder
Data center cost management: billing: sub feeder
Buildings medium building network management: main incomer
Buildings medium building cost management: cost allocation: main incomer
Buildings medium building cost management: billing: main incomer
Buildings medium building cost management: cost allocation: sub feeder
Buildings medium building cost management: billing: sub feeder
Buildings medium building network management: sub feeder
Buildings multi-site cost management: cost allocation: main incomer
Buildings multi-site cost management: billing: main incomer
Buildings multi-site network management: sub feeder
Buildings multi-site cost management: cost allocation: sub feeder
Buildings multi-site cost management: billing: sub feeder
Buildings small building cost management: billing: main incomer
Buildings large building cost management: cost allocation: main incomer
Buildings large building cost management: billing: main incomer
Buildings large building network management: sub feeder
Buildings large building cost management: cost allocation: sub feeder
Buildings large building cost management: billing: sub feeder
Healthcare cost management: cost allocation: main incomer
Healthcare cost management: billing: main incomer
Healthcare network management: sub feeder
Healthcare cost management: cost allocation: sub feeder
Healthcare cost management: billing: sub feeder
Type of measurement
Active power
Reactive power
Energy
Power factor
Frequency
Voltage
THD (U) per phase
THD (I) per phase
Current
Voltage measurement range
20-400 V AC 45...65 Hz between phase and neutral
35-690 V AC 45...65 Hz between phases
Complementary Width
96 mm
Enviroment
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...85 °C
Electromagnetic compatibility
Electrostatic discharge level 4 conforming to IEC 61000-4-2
Limits for harmonic current emissions class A conforming to IEC 61000-3-2
Magnetic field at power frequency level 4 conforming to IEC 61000-4-8
Conducted and radiated emissions class B conforming to EN 55022
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
IP degree of protection
IP30 body: conforming to IEC 60529
IP52 front: conforming to IEC 60529
Operating altitude
< 2000 m
Relative humidity
5...95 % at 50 °C
Standards
EN 50470-1
EN 50470-3
IEC 60529
IEC 61557-12
IEC 62053-22
IEC 62053-24
UL 61010-1