Energy sensor PowerTag 63A 3P top or bottom position of the breaker or switch

Short description

Energy sensor PowerTag 63A 3P top or bottom position of the breaker or switch

Brand
Schneider Electric
Product name
PowerTag
Accuracy class [Ea]
Class 1
Best for
Switchboard upgrade
Communication
Modbus TCP/IP
Concentrator compatibility
Acti9 Smartlink SI B
Acti9 Smartlink SI D
EcoStruxure Panel Server Entry PAS400
EcoStruxure Panel Server Universal (PAS600L/PAS600T)
EcoStruxure Panel Server Universal (PAS800/PAS800L/PAS800P)
PrismaSet Active
Current measurement method
Direct input
Current measurement range
0…63 A
Device application
Overload alarm
Breaker voltage monitoring
Sub billing
MID compliant
No
Mounting mode
On breaker
Multi-tariff
No
Poles description
3P
Power quality data
Yes (PF only)
Rated current [In]
63 A
Type of measurement
Active energy
Active power
Power factor
Voltage
Current

10 pieces available in 2-4 days

11+ pieces available in 4-6 days

146,00  excl. VAT
Price Range
Amount (pcs)Price
1+146.00 €
5+144.00 €
10+141.00 €

Description

PowerLogic PowerTag Energy M63 3P is a wireless communication energy sensor. It is intended for Schneider Electric’s range Acti9 and Multi9 3P Monoconnect devices with 18mm pitch between phase and neutral, rating less than or equal 63A. Might be compatible with other producers (e.g ABB, EATON, Legrand, Schrack, ETI etc.). It has to be associated with a concentrator or a gateway to provide circuit monitoring and diagnosis down to load level. It is made especially for Energy Management, Energy Efficiency, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active energy, active power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy 63A complies with IEC 61557-12 standard. It is a PMD-I/DD/K55/1. Class performance fits under Class 1. The Imax Maximum current is 63A. The Ib Base current is 10A. The Saturation current is 130A. The Ist Starting current is 40mA. The Un rated voltage is Phase-to-phase 380VAC to 415VAC +/- 20%. The maximum consumption is below or equal to 2VA. It may be installed either on the top or the bottom of the protective device. The product color is white (RAL9003). The weight is 28g. Dedicated wireless Zigbee concentrator is necessary do conclude energy monitoring solution. Wireless PowerTag display A9XMWRD is optional.

Specifications

Main
Accuracy class
Class 0.5 voltage conforming to IEC 61557-12
Class 1 active energy conforming to IEC 61557-12
Class 1 active power conforming to IEC 61557-12
Class 1 power factor conforming to IEC 61557-12
Class 1 current conforming to IEC 61557-12
Basic current [Ib]
10A
Device short name
PowerTag
Mounting location
Top or bottom
Mounting support
On circuit breaker
Power quality analysis
Power factor (PF)
Product or component type
Energy meter
Range compatibility
Acti 9 DT60
Acti 9 iC60 single terminal
Acti 9 iKQ
Acti 9 iKQE RCBO
Acti 9 Reflex iC60
Acti9 iC65
Acti9 iID
Acti9 iID K
Acti9 iK60
Acti9 K60
Multi 9 C32N
Multi 9 C60
Multi 9 C65
Multi 9 ID
Range of product
PowerLogic
Saturation current
130 A
Starting current
40 mA
Type of measurement
Active energy
Active power
Power factor
Voltage
Current
Complementary
Cable cross section
1 stranded cable 1.5-16 mm²
1 rigid cable 1.5-16 mm²
2 stranded cable 1.5-2.5 mm²
2 rigid cable 1.5-2.5 mm²
Colour
White (RAL 9003)
Communication port protocol
Modbus TCP/IP (concentrator)
Communication port support
Ethernet (concentrator)
Complementary Depth
43 mm
Complementary Height
16.5 mm
Mounting support
On circuit breaker
Net weight
28 g
Network frequency
50 Hz
60 Hz
Rated insulation voltage [Ui]
380...415 V AC, +/- 20 %, between phases
Standards
ETSI EN 300 328
ETSI EN 301 487-1
IEC 61010-2-030
IEC 61010-1
IEC 61326-1
IEC 61557-12
Target application
Buildings: overload alarm
Buildings: breaker voltage monitoring
Buildings: cost allocation
Transmission support medium
Radio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4
Type of measurement
Active energy
Active power
Power factor
Voltage
Current
Complementary Width
54 mm
Enviroment
Ambient air temperature for operation
-25...60 °C
Ambient air temperature for storage
-40...85 °C
Directives
2014/53/EU - radio equipment directive
Electromagnetic compatibility
Electromagnetic emission conforming to IEC 62311
Industrial electromagnetic environment conforming to IEC 61326-1
Radiated EMC conforming to ETSI EN 301 489-17
Environmental characteristic
Indoor use
Dustproof class 3S3 conforming to IEC 60721-3-3
Salt mist class 3C2 conforming to IEC 60721-3-3
IK degree of protection
IK05
IP degree of protection
IP20 conforming to IEC 60529
Net weight
28 g
Operating altitude
< 2000 m
Overvoltage category
III conforming to IEC 61010-1
Relative humidity
0...95 % at 45 °C conforming to IEC 60721-3-3
Standards
ETSI EN 300 328
ETSI EN 301 487-1
IEC 61010-2-030
IEC 61010-1
IEC 61326-1
IEC 61557-12